How To Order

How to Specify and Order Pumps from Air Dimensions Incorporated

 

 

B-Series

CapacityWetted MaterialsMotorOptional
StyleEccentricHeadsHeadDiaphragmTypeVoltageFrequency/PhaseOptions
B=Micro161A=AluminumE=Encapsulated*A=General PurposeA=1150=N/AC=Motor Cover
142B=Teflon Coated AluminumP=2-Ply TeflonJ†= Brush DCB=2301=60 Hz 1 PhL=Elevated Head
12F=316 SSP† = Speed Control Brushless DCH=122=50 Hz 1 PhM=Heated w/ K Thermocouple
10G=Teflon Coated 316 SST= Brushless DCJ=24M1=Heated w/ PT100 RTD
08L=SilcoNert™ 2000 316 SSZ=Rotate Housing 180°
T=Solid Teflon*

*Solid Teflon Head and Encapsulated Diaphragm must be used together
 24 VDC only

Example: B161-FP-AA1 = Single Head Micro Dia-Vac® pump, 316 ss wetted parts, All-Teflon diaphragm, 115v/60Hz GP motor

J-Series

CapacityWetted MaterialsMotorOptional
StyleEccentricHeadsHeadDiaphragmTypeVoltageFrequency/PhaseOptions
J=Macro161A=AluminumF=Teflon/VitonA=General PurposeA=1150=N/AC=Motor Cover
14B=Teflon Coated AluminumP=2-Ply TeflonG=ATEX Zone 1B=2301=60 Hz 1 PhL=Elevated Head
F=316 SSP† = Speed Control Brushless DCH=122=50 Hz 1 PhM=Heated w/ K Thermocouple
G=Teflon Coated 316 SST= Brushless DCJ=24M1=Heated w/ PT100 RTD
L=SilcoNert™ 2000 316 SS

Example: J161-AF-AA1 = Macro Dia-Vac® pump, Aluminum wetted parts, Teflon/Viton diaphragm 115v 60Hz GP motor
† 24 VDC only

M-Series

CapacityWetted MaterialsMotorOptional
StyleEccentricHeadsHeadDiaphragmTypeVoltageFrequency/PhaseOptions
M=Mini161A=AluminumE=Encapsulated*C=General PurposeA=1150=N/AL=Elevated Head
152B=Teflon Coated AluminumP=2-Ply TeflonW=Class I Division II (UL)B=2301=60 Hz 1 PhM=Heated w/ K Thermocouple
14F=316 SST=Teflon/EPDMZ=ATEX Zone 2 IICX=N/A2=50 Hz 1 PhM1=Heated w/ PT100 RTD
12G=Teflon Coated 316 SSM2=Heated w/ 65° C Thermostat
10H=Hastelloy CM3=Heated w/ 100° C Thermostat
 08J=Teflon Coated Hastelloy CM4=Heated w/ 140° C Thermostat
L=SilcoNert™ 2000 316 SSM5=Heated w/ 163° C Thermostat
P=Electro Polished 316 SSM6=Heated w/ 200° C Thermostat
T=Solid Teflon*

*Solid Teflon Head and Encapsulated Diaphragm must be used together

Example: M161-FT-CA1 = Single Head Mini Dia-Vac® Pump, 316 ss wetted parts, Teflon/EPDM, 115v/60Hz General Purpose motor

R-Series

CapacityWetted MaterialsMotorOptional
StyleEccentricHeadsHeadDiaphragmTypeVoltageFrequency/PhaseOptionsOptions
R=Standard271A=AluminumE=Encapsulated*A=General PurposeA=1150=N/AA=416 SS Valve DiscsM1=Heated w/ PT 100 RTD
Z=Motorless252B=Teflon Coated AluminumP=3-Ply TeflonB=High SpeedB=2301=60 Hz 1 PhB=Head at Both EndsM2=Heated w/ 65° C Thermostat
224F=316 SST=Teflon/EPDMC=TEFC 1/3 HPD=220/3802=50 Hz 1 PhC=Power Cord**M3=Heated w/ 100° C Thermostat
206G=Teflon Coated 316 SSV= VitonD=Air DrivenE=230/4603=60 Hz 3 PhD=Double DiaphragmM4=Heated w/ 140° C Thermostat
18H=Hastelloy CG=ATEX/IECEx IICX=N/A4=50 Hz 3 PhE2=Extended HeadM5=Heated w/ 163° C Thermostat
15J=Teflon Coated Hastelloy CF=ATEX/IECEx IIC 1/2 HPG=EPDM GasketM6=Heated w/ 200° C Thermostat
12L=SilcoNert™ 2000 316 SSM=TEFC 1/2 HPH=Viton GasketM8=Heated w/ Steam
10P=Electro Polished 316 SSN=Div 1 Gr C,D 1/2 HPL=Elevated HeadX=Rotate Housing 90° CW
08T=Solid Teflon*R=Div 1 Gr B,C,D 1/6 HPM=Heated w/ K ThermocoupleY=Rotate Housing 90° CCW
06Z=Rotate Housing 180°

*Solid Teflon Head and Encapsulated Diaphragm must be used together

**Power cord is only available with a General Purpose motor

Example: R221-FT-AA1 = Single Head Dia-Vac pump, 316 ss wetted parts, Teflon/EPDM diaphragm, 115v/60Hz GP motor

RVA-Series Hi-Vacuum

CapacityWetted MaterialsMotorOptional
StyleHeadsHeadDiaphragmTypeVoltageFrequency/PhaseOptions
RVA=Hi-Vacuum1F=316 SSP=3-Ply TeflonA=General PurposeA=1150=N/AC=Power Cord
2T=Teflon/EPDMB=High SpeedB=2301=60 Hz 1 Ph
4C=TEFCD=220/3802=50 Hz 1 Ph
F=ATEX/IECEx IIC 1/2 HPE=230/460 3=60 Hz 3 Ph
G=ATEX/IECEx IIC 1/4 HP 4=50 Hz 3 Ph
M=TEFC 1/2 HP
 N=Div 1 Gr C,D 1/2 HP
 R=Div 1 Gr B,C,D 1/6 HP

Example: RVA1-FT-AA1 = Single Head Hi-Vacuum pump, 316 ss wetted parts, Teflon/EPDM diaphragm, 115v/60Hz GP motor

H-Series

CapacityWetted MaterialsMotorOptional
StyleEccentricHeadsHeadDiaphragmTypeVoltageFrequency/PhaseOptions
H=High Performance301F=316 SSP=3-Ply TeflonA=General PurposeA=1150=N/AC=Power Cord*
2L=SilcoNert™ 2000 316 SST=Teflon/EPDMF=ATEX IIC 1/2 HPB=2301=60 Hz 1 PhM=Heated w/ K Thermocouple
G=ATEX IIC 1/4 HPD=220/3802=50 Hz 1 PhM1=Heated w/ PT100 RTD
 M=TEFC 1/2 HPE=230/460 3=60 Hz 3 Ph M2=Heated w/ 65° C Thermostat
 N=Div 1 Gr C,D 1/2 HP 4=50 Hz 3 Ph M3=Heated w/ 100° C Thermostat
R=Div 1 Gr B,C,D 1/6 HPM4=Heated w/ 140° C Thermostat
M5=Heated w/ 163° C Thermostat
M6=Heated w/ 200° C Thermostat

*Power cord is only available with a General Purpose motor

Example: H302-FT-AA1 = Double Head Hi-Performance Dia-Vac® pump with 316 ss wetted parts, Teflon/EPDM diaphragm, 115v 60Hz GP motor

E-Series

CapacityWetted MaterialsMotorOptional
StyleEccentricHeadsHeadDiaphragmTypeVoltageFrequency/PhaseOptions
E=Extreme Performance251F=316 SSP=3-Ply TeflonA=General PurposeA=1151=60 Hz 1 PhM=Heated w/ K Thermocouple
L=SilcoNert™ 2000 316 SSF=ATEX IIC 1/2 HPB=2302=50 Hz 1 Ph
 N=Div 1 Gr C,D 1/2 HP

Example: E251-FP-AA1 = E-Series Dia-Vac® pump with 316 ss wetted parts, All-Teflon diaphragm, 115v 60Hz GP motor