How can we help you?

Head Connection Schematics

Dia Vac Head Connection Configurations

Standard Dia-Vac® – Head Connection Configurations

Head Connection SchematicDescriptionStandard Eccentric
Minimum Pressure** /
Minimum Vacuum ** /
CFM at 0 PSIG **
Systems Applications
2-header-independent-500.jpgDouble headed pump,
both heads operating independently.
40 PSIG Pressure
25 InHg Vacuum
0.9 CFM each head.
For economical use of 2 heads pumping separately.
2-header-parallel-500.jpgDouble headed pump,
both heads in parallel.
40 PSIG Pressure
25 InHg Vacuum
1.7 CFM at 0 InHg.
For higher flow capacity.
2-header-series-500.jpgDouble headed pump,
series connected.
75 PSIG Limited. *
28 InHg Vacuum
0.9 CFM at 0 PSIG.
For higher vacuum or pressure.
4-header-parallel-500.jpgQuad headed pump,
all heads in parallel.
40 PSIG Pressure
25 InHg Vacuum
0.9 CFM each head (3.6 total).
For higher flow capacity.
4-header-series-500.jpgQuad headed pump,
all heads in series.
60 PSIG Limited. *
29.5 InHg Vacuum
0.9 CFM.
For higher vacuum capacity.
4-header-series-parallel-500.jpgQuad headed pump,
parallel connection of two pairs of heads in series.
75 PSIG Limited. *
28 InHg Vacuum
1.7 CFM.
For higher vacuum & flow capacity.