954-428-7333



How To Order

How to Specify and Order Pumps from Air Dimensions Incorporated

B-Series

Capacity Wetted Materials Motor Optional
Style Eccentric Heads Head Diaphragm Type Voltage Frequency/Phase Options
B=Micro 16 1 A=Aluminum E=Encapsulated* A=General Purpose A=115 0=N/A A=Aluminum Spacer
14 2 B=Teflon Coated Aluminum P=2-Ply Teflon H= Brushless DC (CE) B=230 1=60 Hz 1 Ph L=Elevated Head
12 F=316 SS J= Brush DC H=12 2=50 Hz 1 Ph LA=Elevated w/ Aluminum Spacer
10 G=Teflon Coated 316 SS P = Speed Control Brushless DC J=24 M**=Heated w/ K Thermocouple
08 L=SilcoNert™ 2000 316 SS T = Brushless DC M1**=Heated w/ PT100 RTD
T=Solid Teflon* Z=Rotate Housing 180°

*Solid Teflon Head and Encapsulated Diaphragm must be used together
** Please make sure to inform Air Dimensions representatives if the gas temperature will be above 350 °F
24 VDC only
12 VDC only

Example: B161-FP-AA1 = Single Head Micro Dia-Vac® pump, 316 ss wetted parts, All-Teflon diaphragm, 115v/60Hz GP motor

J-Series

Capacity Wetted Materials Motor Optional
Style Eccentric Heads Head Diaphragm Type Voltage Frequency/Phase Options
J=Macro 16 1 A=Aluminum F=Teflon/Viton A=General Purpose A=115 0=N/A L=Elevated Head
14 B=Teflon Coated Aluminum P=2-Ply Teflon H= Brushless DC (CE) B=230 1=60 Hz 1 Ph M=Heated w/ K Thermocouple
F=316 SS J= Brush DC H=12 2=50 Hz 1 Ph M1=Heated w/ PT100 RTD
G=Teflon Coated 316 SS J=24
L=SilcoNert™ 2000 316 SS

 

Example: J161-AF-AA1 = Macro Dia-Vac® pump, Aluminum wetted parts, Teflon/Viton diaphragm 115v 60Hz GP motor

M-Series

Capacity Wetted Materials Motor Optional
Style Eccentric Heads Head Diaphragm Type Voltage Frequency/Phase Options
M=Mini 16 1 A=Aluminum E=Encapsulated* A=General Purpose A=115 0=N/A L=Elevated Head
15 2 B=Teflon Coated Aluminum N=EPDM D=Air Driven B=230 1=60 Hz 1 Ph M=Heated w/ K Thermocouple
14 F=316 SS  P=2-Ply Teflon W=Class I Division II X=N/A 2=50 Hz 1 Ph M1=Heated w/ PT100 RTD
12 G=Teflon Coated 316 SS  T=Teflon/EPDM  Z=ATEX Zone 2 IIC M2=Heated w/ 65° C Thermostat
10 H=Hastelloy C M3=Heated w/ 100° C Thermostat
 08 J=Teflon Coated Hastelloy C M4=Heated w/ 140° C Thermostat
L=SilcoNert™ 2000 316 SS M5=Heated w/ 163° C Thermostat
P=Electro Polished 316 SS M6=Heated w/ 200° C Thermostat
T=Solid Teflon*

*Solid Teflon Head and Encapsulated Diaphragm must be used together

Example: M161-FT-AA1 = Single Head Mini Dia-Vac® Pump, 316 ss wetted parts, Teflon/EPDM, 115v/60Hz General Purpose motor

R-Series

Capacity Wetted Materials Motor Optional
Style Eccentric Heads Head Diaphragm Type Voltage Frequency/Phase Options Options
R=Standard 27 1 A=Aluminum E=Encapsulated* A=General Purpose A=115 0=N/A A=416 SS Valve Discs M1=Heated w/ PT 100 RTD
Z=Motorless 25 2 B=Teflon Coated Aluminum N=EPDM C=TEFC 1/3 HP B=230 1=60 Hz 1 Ph B=Head at Both Ends M2=Heated w/ 65° C Thermostat
22 4 F=316 SS P=3-Ply Teflon D=Air Driven D=220/380 2=50 Hz 1 Ph C=Power Cord** M3=Heated w/ 100° C Thermostat
20 6 G=Teflon Coated 316 SS T=Teflon/EPDM F=ATEX/IECEx IIC 1/2 HP E=230/460 3=60 Hz 3 Ph D=Double Diaphragm M4=Heated w/ 140° C Thermostat
18  8 H=Hastelloy C V=Viton G=ATEX/IECEx IIC 1/4 HP F=460 4=50 Hz 3 Ph E=Extended Head M5=Heated w/ 163° C Thermostat
15 J=Teflon Coated Hastelloy C M=TEFC 1/2 HP X=N/A E1=Extended Head M6=Heated w/ 200° C Thermostat
12 L=SilcoNert™ 2000 316 SS N=Div 1 Gr C,D 1/2 HP G=EPDM Gasket M8=Heated w/ Steam
10 P=Electro Polished 316 SS R=Div 1 Gr B,C,D 1/6 HP H=Viton Gasket X=Rotate Housing 90° CW
08 T=Solid Teflon* L=Elevated Head Y=Rotate Housing 90° CCW
06  M=Heated w/ K Thermocouple Z=Rotate Housing 180°

*Solid Teflon Head and Encapsulated Diaphragm must be used together

**Power cord is only available with a General Purpose motor

Example: R221-FT-AA1 = Single Head Dia-Vac pump, 316 ss wetted parts, Teflon/EPDM diaphragm, 115v/60Hz GP motor

R-Series Hi-Vacuum

Capacity Wetted Materials Motor Optional
Style Heads Head Diaphragm Type Voltage Frequency/Phase Options
RVA=Hi-Vacuum 1 F=316 SS N=EPDM A=General Purpose A=115 0=N/A C=Power Cord**
2 P=3-Ply Teflon C=TEFC 1/3 HP B=230 1=60 Hz 1 Ph E=Extended Head
4 T=Teflon/EPDM D=Air Driven D=220/380 2=50 Hz 1 Ph E1=Extended Head
V=Viton F=ATEX/IECEx IIC 1/2 HP E=230/460 3=60 Hz 3 Ph L=Elevated Head
G=ATEX/IECEx IIC 1/4 HP F=460 4=50 Hz 3 Ph X=Rotate Housing 90° CW
M=TEFC 1/2 HP X=N/A Y=Rotate Housing 90° CCW
N=Div 1 Gr C,D 1/2 HP Z=Rotate Housing 180°
R=Div 1 Gr B,C,D 1/6 HP

Example: RVA1-FT-AA1 = Single Head Hi-Vacuum pump, 316 ss wetted parts, Teflon/EPDM diaphragm, 115v/60Hz GP motor

H-Series

Capacity Wetted Materials Motor Optional
Style Eccentric Heads Head Diaphragm Type Voltage Frequency/Phase Options
H=High Performance 30 1 F=316 SS P=3-Ply Teflon A=General Purpose A=115 0=N/A C=Power Cord*
2 L=SilcoNert™ 2000 316 SS T=Teflon/EPDM F=ATEX IIC 1/2 HP B=230 1=60 Hz 1 Ph M=Heated w/ K Thermocouple
G=ATEX IIC 1/4 HP D=220/380 2=50 Hz 1 Ph M1=Heated w/ PT100 RTD
 M=TEFC 1/2 HP E=230/460  3=60 Hz 3 Ph  M2=Heated w/ 65° C Thermostat
 N=Div 1 Gr C,D 1/2 HP  4=50 Hz 3 Ph  M3=Heated w/ 100° C Thermostat
R=Div 1 Gr B,C,D 1/6 HP M4=Heated w/ 140° C Thermostat
M5=Heated w/ 163° C Thermostat
M6=Heated w/ 200° C Thermostat

*Power cord is only available with a General Purpose motor

Example: H302-FT-AA1 = Double Head Hi-Performance Dia-Vac® pump with 316 ss wetted parts, Teflon/EPDM diaphragm, 115v 60Hz GP motor

E-Series

Capacity Wetted Materials Motor Optional
Style Eccentric Heads Head Diaphragm Type Voltage Frequency/Phase Options
E=Extreme Performance 25 1 F=316 SS P=3-Ply Teflon A=General Purpose A=115 1=60 Hz 1 Ph M=Heated w/ K Thermocouple
L=SilcoNert™ 2000 316 SS F=ATEX IIC 1/2 HP B=230 2=50 Hz 1 Ph
 N=Div 1 Gr C,D 1/2 HP

 

Example: E251-FP-AA1 = E-Series Dia-Vac® pump with 316 ss wetted parts, All-Teflon diaphragm, 115v 60Hz GP motor